Fire Alarm >> Smoke Detectors

  Multi Purpose Smoke & Heat Detector

Advance multi-Sensor is microprocessor based smoke detector that uses a combination of photoelectric and thermal sensing technologies. It provides early warning and an accurate analysis of alarm situation. These state of the art algorithms also provide a high immunity to nuisance alarm

Sensitivity Setting : Comply to UL & EN Standard
Material : Fire - proof Plastic
  Multi Purpose Smoke & Heat Detector
 

The infrared light beam from Transmitter intersects the smoke particles will cause the light spread to all directions. When Receiver senses the light, it will send signal to control panel for fire alarm status as soon as the density of smoke reaches per-determind alarm level

Sensitivity Setting: Comply to UL268, EN54 Standard
Material : Fire - proof Plastic
  Photo electric smoke _ UL

The infrared light beam from Transmitter intersects the smoke particles, It will cause the light to spread to all directions. When receiver has sensed the light, it will send signal to control panel for fire alarm status as soon as the density of smoke reaches per determinedalarm level.

Sensitivity Setting : 1.5 ~ 2.80 % ft
Material : Fire - proof Plastic

  Photo electric smoke_CE

The infrared light beam from Transmitter intersects the smoke particles will cause the light spread to all directions. When receiver has sensed the light it will send signal to control panel for alarm status as soon as the density of smoke reaches per determined alarm level.

Ambient Temperature : -10 °C ~ +55 °C
Material : Fire - proof Plastic
  Rate Of Rise

When detector's ambient temperature rises rapidly and has reached the pre-fire standard ( operating temperature ), inside of detector will inflate and then press the sensing diaphragm to conduct the metal contact. Thus the fire signal will be sent to control panel. Detector itself has auto balance function when temperature changed rapidly, so false alarm wouldn't happen.

Ambient Temperature : 0 °C ~ +55 °C
Material : Fire - proof Plastic
  Single Station Smoke Detector

Once battery is connected, detector , will start normal operation after 25 seconds internal charging. When smoke density exceeds preset standard during per-fire period, the refraction phenomenon will caused by scattering light between receiver and transmitter inside the smoke chamber. Then initial the inspection system and issue alarm sound which is per-fire warning.

Operating Density : Comply to UL217, EN 54, CNS
Material : Fire - proof Plastic